A bright white, non-aqueous developer, SKD-S2 creates an opaque white background for high-contrast penetrant testing and quickly draws penetrant out to create stronger, clearer indications for better inspection reliability and sensitivity. Noted for its compatibility with special alloys, such as stainless steel, aluminum, magnesium and titanium, SKD-S2 is non-halogenated, can be used with Type 1 and Type 2 penetrants. This solvent-based developer meets aerospace and nuclear industry requirements, and complies with all major NDT specifications, including ISO 3452. SKD-S2 helps speed up the inspection process by going on easily, drying quickly, promoting faster indication formation and minimizing post-inspection cleaning. It is ideal for machine shops, weld testing and field applications. SKD-S2 is listed on the QPL SAE AMS 2644 Qualified Product List and is approved by numerous Aerospace Primes including, Boeing, GE and Honeywell.
Features
A bright white, non-aqueous developer, SKD-S2 creates an opaque white background for high-contrast penetrant testing and quickly draws penetrant out to create stronger, clearer indications
SKD-S2 is non-halogenated
Can be used with Type 1 and Type 2 penetrants
Helps speed up the inspection process by going on easily, drying quickly, promoting faster indication formation and minimizing post-inspection cleaning
Specifications
AECL
AMS 2644
ASME BPVC
ASTM E1417
Boeing BAC 5423 PSD 6-46 or 8-4
Boeing PS-21202
GE P3TF2
GE P50YP107
Honeywell EMS 52309
ISO 3452-2
NAVSEA 250-1500-1
NAVSEA T9074-AS-GIB-010/271
QPL SAE AMS 2644
Applications
Ideal Applications: Field applications
Machine shops
Welds
Caution
Danger: Highly flammable liquid and vapor.
Causes serious eye irritation.
May cause drowsiness or dizziness.
Keep away from heat, sparks, open flames and hot surfaces.
No smoking. Keep container tightly closed.
Ground/Bond container and receiving equipment. Use explosion-proof electrical, ventilating and lighting equipment. Use only non-sparking tools. Take precautionary measures against static discharge.
Wear protective gloves, eye protection and face protection.
Wash hands thoroughly after handling.
Avoid breathing dust, fumes, gas, mist, vapours and spray. Use only outdoors or in a well-ventilated area.
If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
If eye irritation persists: Get medical advice/attention.
If inhaled: Remove person to fresh air and keep comfortable for breathing. Call a poison center/doctor if you feel unwell.
Store in a well-ventilated place
Keep cool
Store locked up